EnerPower VC+ 18650 3000mAh (Purple)
/DSC_8704.jpg)
Official specifications:
- Recommended maximum current: 12-14A
- Initial IR (1kHz): <18mOhm
- Initial IR (DC): <30mOhm
- Charge method: CC-CV (4.2V+/-0.05V, 100mA cut-off)
- Standard charge current: 1.5A
- Fast charge current: 4A
- End voltage: 2.5V
- Max. continuous current: 15A
- Rated discharge capacity (0.2C): 3000mAh
- Rated discharge capacity (10A): 2700mAh
- Cycle life: 300 cycles to 70% (4A charge and 15A discharge)
- Cycle life: 250 cycles to 70% (4A charge and 22A discharge, pause at 70°C, resume at 50°C)
/EnerPower%20VC+%2018650%203000mAh%20(Purple)-info.png)
These cells are a test of a high performance protection, it has lover resistance and can handle higher current than usual protections.
/DSC_8703.jpg)
/DSC_8706.jpg)
/DSC_8707.jpg)
/DSC_8708.jpg)
/DSC_8709.jpg)
/EnerPower%20VC+%2018650%203000mAh%20(Purple)-Capacity.png)
The discharge chart shows a very good cell and the new protetion means less voltage drop due to protection
/EnerPower%20VC+%2018650%203000mAh%20(Purple)-Temp-15.0.png)
/EnerPower%20VC+%2018650%203000mAh%20(Purple)-Temp-20.0.png)
This current trips the protection after some time and the cell will not get hot.
/EnerPower%20VC+%2018650%203000mAh%20(Purple)-CapacityTimeHours.png)
/EnerPower%20VC+%2018650%203000mAh%20(Purple)-CapacityTime.png)
/EnerPower%20VC+%2018650%203000mAh%20(Purple)-Energy.png)
/EnerPower%20VC+%2018650%203000mAh%20(Purple)-PowerLoadTime.png)
/EnerPower%20VC+%2018650%203000mAh%20(Purple)-TripCurrent.png)
I did not adjust my test to handle higher protection currents, the trip point is somewhere above 20A
/EnerPower%20VC+%2018650%203000mAh%20(Purple)-Charge.png)
Conclusion
This battery has lower voltage drops than other protected batteries with the same cell. For anything in the 3A up to 7A - 10A this cell is a very good option for a protected battery.
Notes and links
The batteries was supplied by Enerpower for review.
How is the test done and how to read the charts
How is a protected LiIon battery constructed
More about button top and flat top batteries
Compare to 18650 and other batteries